How to properly disinfect the potting machine

The application field of the filling machine industry is very extensive, and its important applications in the food, daily chemical, pharmaceutical and other industries fully explain its importance, and it is closely related to people's daily life, which is needed when using the filling machine. Some disinfection and cleaning work done may not be well understood. Here are some points for you:

First, the frequency of cleaning:

1. Before production and after production: clean and disinfect 1 time.

2. When replacing the variety, it must be cleaned and disinfected according to this procedure.

3, equipment maintenance must be thoroughly cleaned and disinfected.

Second, cleaning tools:

Sterilized cleaning cloth, rubber gloves, brush, cleaning pot, tweezers, and tweezers that do not fall off the fibers.

Third, disinfectant:

1. 0.2% benzalkonium solution;

2. 75% ethanol solution.

Fourth, cleaning, disinfection methods:

1. Before the production operation: clean and disinfect the potting machine into the bottle hopper, the bottle hopper, the tooth plate and the outer wall with disinfectant.

2. After the end of production: close the gas valve, turn off the power switch, unplug the power plug, remove the perfusion system, and place it in the designated container.

3. Remove the broken glass chips from the bottle, the bottle, the tooth plate and the potting machine.

4. Wipe the liquid and grease on the bottle, the bottle, the tooth plate and the potting machine with a sterile cleaning cloth, and wipe it with a dry sterilization cloth.

5. Clean and disinfect the bottle into the bottle, out of the bottle, the tooth plate and the outer wall of the potting machine with disinfectant.

6. Remove the ground glass swarf around the potting machine and clean and disinfect the floor with disinfectant.

7. After the potting machine is cleaned and disinfected, fill in the equipment cleaning record, pass the QA inspector's inspection, and hang the “cleaned” status label card, and exit the potting chamber to close the door.

Fifth, the perfusion system is clean and sterilized:

1. In the clean room clean room, rinse the parts with purified water and soak them in 3% hydrogen peroxide for 8 hours to remove the pyrogen.

2. The hydrogen peroxide was poured off, and the parts were rinsed with water for injection filtered through a 0.22 m filter for 5 minutes, placed in a designated clean container, and sterilized at 132 ° C for 5 minutes in a pulsating vacuum sterilizer.