Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen

Model NO.: HBHKN-2001
OEM&ODM: Available
Power Requirement: AC22ov-230V/5ohz or AC11o-120V/50-6ohz, 900va
Baby Mode Temperature Control Range: 34.5-37.5°c
Accuracy of Skin Temperature Sensor: ±0.2°c
Mattress Heating Control Range: 25-38°c
Accuracy of Mattress Temperature Display: ±0.7°c
Ambient Air Movement Rate: <O.3m/S
Inclination of Bassinet: Trendelenburg Is 15°, Reverse Trendelenburg Is
Package Gross Weight: 250 Kg
Trademark: WANROOEMED
Transport Package: Export Package
Specification: l500mmx8l0mmxl475mm
Origin: China
HS Code: 94029000
Model NO.: HBHKN-2001
OEM&ODM: Available
Power Requirement: AC22ov-230V/5ohz or AC11o-120V/50-6ohz, 900va
Baby Mode Temperature Control Range: 34.5-37.5°c
Accuracy of Skin Temperature Sensor: ±0.2°c
Mattress Heating Control Range: 25-38°c
Accuracy of Mattress Temperature Display: ±0.7°c
Ambient Air Movement Rate: <O.3m/S
Inclination of Bassinet: Trendelenburg Is 15°, Reverse Trendelenburg Is
Package Gross Weight: 250 Kg
Trademark: WANROOEMED
Transport Package: Export Package
Specification: l500mmx8l0mmxl475mm
Origin: China
HS Code: 94029000
HBHKN-2001 Baby Care Equipments Infant Radiant Warmer with LED Display Screen
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand.
 

Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, J.V. Pole, mattress, tray and panels
 

Specification:
Power requirement: AC22OV-230V/5OHz or AC11O-120V/50-6OHz, 900VA Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro - computer
Baby mode temperature control range: 34.5-37.5°C
Accuracy of skin temperature sensor: ±0.2°C
Temperature uniformity of mattress: <= 2°C
Mattress heating control range: 25-38°C
Accuracy of mattress temperature display: ±0.7°C
Angle of warmer module: ±60°
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50"~ 1', 4'50" ~5', 9' 50"~ 10'
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: 1mW/cm2
Average value general bilirubin radiation of on the mattress effective range:
≥0.8mW/cm2
Bilirubin uniformity of radiating on the mattress effective range: >0.4
 

Environmental temperature:
Operating range: 18 °C -30°C
Ambient air movement rate:  

Product Packaging:
Package: each unit is packed into one carton
Dimension: l500mmx8l0mmxl475mm
Gross Weight: 250 Kg


Details:
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen

Company Information:
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
  HBHKN-2001 Baby Care Equipments Infant Radiant Warmer with LED Display Screen
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand.
 

Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, J.V. Pole, mattress, tray and panels
 

Specification:
Power requirement: AC22OV-230V/5OHz or AC11O-120V/50-6OHz, 900VA Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro - computer
Baby mode temperature control range: 34.5-37.5°C
Accuracy of skin temperature sensor: ±0.2°C
Temperature uniformity of mattress: <= 2°C
Mattress heating control range: 25-38°C
Accuracy of mattress temperature display: ±0.7°C
Angle of warmer module: ±60°
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50"~ 1', 4'50" ~5', 9' 50"~ 10'
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: 1mW/cm2
Average value general bilirubin radiation of on the mattress effective range:
≥0.8mW/cm2
Bilirubin uniformity of radiating on the mattress effective range: >0.4
 

Environmental temperature:
Operating range: 18 °C -30°C
Ambient air movement rate:  

Product Packaging:
Package: each unit is packed into one carton
Dimension: l500mmx8l0mmxl475mm
Gross Weight: 250 Kg


Details:
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen

Company Information:
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
Hbhkn-2001 Baby Care Infant Radiant Warmer with LED Display Screen
 

Frozen Vegetables & Fruits

Frozen Cauliflower,IQF Cauliflower,High Quality Cauliflower

Ginger,Garlic &Peeled Garlic, Co., Ltd. , http://www.nsvegetables.com